{"id":1069,"date":"2021-11-14T11:37:14","date_gmt":"2021-11-14T03:37:14","guid":{"rendered":"http:\/\/frackledesign.com\/uncategorized\/furuisits-warm-reminder-when-winter-is-coming-it-is-time-to-add-antifreeze-to-diesel-generator-sets.html"},"modified":"2022-01-28T17:31:46","modified_gmt":"2022-01-28T09:31:46","slug":"furuisits-warm-reminder-when-winter-is-coming-it-is-time-to-add-antifreeze-to-diesel-generator-sets","status":"publish","type":"post","link":"http:\/\/frackledesign.com\/en\/uncategorized\/furuisits-warm-reminder-when-winter-is-coming-it-is-time-to-add-antifreeze-to-diesel-generator-sets.html","title":{"rendered":"FURUISIt’s warm reminder: when winter is coming, it is time to add antifreeze to diesel generator sets!"},"content":{"rendered":"\n
After entering the winter, the maintenance of diesel generator sets has become a concern of the majority of users. The editor has sorted out the main points of diesel generator set maintenance in winter and daily maintenance for your reading!<\/p>\n\n
1. Fuel replacement<\/p>\n\n
In general, the freezing point of the diesel oil used should be 3-5\u00b0C lower than the lowest temperature in the season to ensure that the lowest temperature will not affect the use due to solidification. usually:<\/p>\n\n
2.Choose the appropriate antifreeze<\/p>\n\n
Change the antifreeze regularly and prevent leaks when adding. Antifreeze is available in red, green and blue. It is easy to find out when leaking. Once it is found, it is necessary to wipe up the leakage and check the leak to select an antifreeze with a suitable freezing point. Generally speaking, the freezing point of the selected antifreeze should preferably be low. At the local minimum temperature of 10 \u2103, leave a little extra to prevent the sudden drop in temperature at certain times.<\/p>\n\n
3. Choose oil with low viscosity<\/p>\n\n
After the temperature drops sharply, the viscosity of the oil will increase, which may be greatly affected during cold start. It is difficult to start and the engine is difficult to rotate. Therefore, when choosing oil for diesel generator sets in winter, it is recommended to replace the oil with a lower viscosity.<\/p>\n\n
4. Replace the air filter<\/p>\n\n
Due to the extremely high requirements for air filter elements and diesel filter elements in cold weather, if they are not replaced in time, the wear of the engine will increase and the service life of the diesel generator set will be affected. Therefore, it is necessary to replace the air filter frequently to reduce the probability of impurities entering the cylinder and prolong the service life and safety of the diesel generator set.<\/p>\n\n
5. Release the cooling water in time<\/p>\n\n
In winter, special attention should be paid to the change of temperature. If the temperature is lower than 4 degrees, the cooling water in the cooling water tank of the diesel engine should be released in time, otherwise the cooling water will expand during the solidification process, which will cause the cooling water tank to burst and damage.<\/p>\n\n
6. Increase the body temperature<\/p>\n\n
When the diesel generator set is started in winter, the temperature of the air sucked in the cylinder is low, and it is difficult for the piston to compress the gas to reach the natural temperature of the diesel. Therefore, corresponding auxiliary methods should be used to increase the temperature of the diesel generator set before starting.<\/p>\n\n
7. Preheat in advance and start slowly<\/p>\n\n
After the diesel generator set is started in winter, it should run at low speed for 3-5 minutes in order to increase the temperature of the whole machine, check the working condition of the lubricating oil, and then put it into normal operation after the inspection is normal. The diesel generator set should try to reduce the sudden acceleration of the speed or the maximum operation of the accelerator during operation, otherwise the service life of the valve assembly will be affected for a long time.<\/p>\n\n
In order to ensure the normal operation of diesel generators and prolong the service life, it is necessary to do daily inspection and maintenance work to ensure that the power supply can be in a good working state immediately when the power is cut off, without affecting the normal power consumption. First of all, you should do a daily inspection, mainly to check the following aspects:<\/p>\n\n
In addition to the above daily maintenance, there are the following items that need to be checked every week.<\/p>\n\n
Generators used in many industries are used as backup power sources. The characteristics of backup power sources are that they are not usually used and can be supplied in time when they are used. To achieve this effect, we must pay attention to the maintenance of diesel generator sets. Because the standby diesel generator set is in a static state for a long time, the various materials of the generator set itself will undergo complex chemical and physical changes with oil, cooling water, diesel oil, air, etc., so that the generator set will be “discharged”. Hope the above will help you!<\/p>\n","protected":false},"excerpt":{"rendered":"
After entering the winter, the maintenance of diesel generator sets has become a concern of the majority of users. The editor has sorted out the main points of diesel generator set maintenance in winter and daily maintenance for your reading! 1. Fuel replacement In general, the freezing point of the diesel oil used should be …<\/p>\n